




{"id":7542,"date":"2025-06-18T06:30:00","date_gmt":"2025-06-18T06:30:00","guid":{"rendered":"https:\/\/realheart.se\/mfn_news\/realheart-publicerar-validerande-data-som-visar-hemodynamisk-balans-och-automatiserad-kontroll-av-hjartminutvolymen\/"},"modified":"2025-06-18T06:30:00","modified_gmt":"2025-06-18T06:30:00","slug":"realheart-publicerar-validerande-data-som-visar-hemodynamisk-balans-och-automatiserad-kontroll-av-hjartminutvolymen","status":"publish","type":"mfn_news","link":"https:\/\/realheart.se\/sv\/mfn_news\/realheart-publicerar-validerande-data-som-visar-hemodynamisk-balans-och-automatiserad-kontroll-av-hjartminutvolymen\/","title":{"rendered":"Realheart publicerar validerande data som visar hemodynamisk balans och automatiserad kontroll av hj\u00e4rtminutvolymen"},"content":{"rendered":"<div class=\"mfn-preamble\">\n<p><strong>V\u00e4ster\u00e5s, Sverige, 18 juni 2025 &#8211; Scandinavian Real Heart AB (publ) meddelar idag att bolagets vetenskapliga samarbetspartner vid Kungliga Tekniska H\u00f6gskolan (KTH) har publicerat nya resultat i den vetenskapliga tidskriften Artificial Organs, som validerar Realheart\u00ae TAH:s funktion att skapa systemisk hemodynamisk balans, samt adaptivt justera systemets hj\u00e4rtminutvolym baserat p\u00e5 data fr\u00e5n trycksensorer. De nya resultaten \u00e4r baserade p\u00e5 simuleringar fr\u00e5n den senaste tekniken av ett semi-virtuellt system som finansierats genom ett gemensamt strategiskt initiativ mellan Vinnova, Formas och Energimyndigheten.<\/strong><\/p>\n<\/div>\n<div class=\"mfn-body\">\n<p>De publicerade resultaten visar att Realheart\u00ae TAHs automatiska kontrollalgoritm uppr\u00e4tth\u00e5ller en korrekt v\u00e4nster-h\u00f6gerbalans, vilket balanserar blodtrycket mellan systemisk cirkulation och lungcirkulation i hj\u00e4rt-k\u00e4rlsystemet. Vidare visar data att Realheart\u00ae TAH automatiskt \u00f6kade hj\u00e4rtminutvolymen med upp till 2,1 g\u00e5nger under tr\u00e4ning fr\u00e5n vila och minskade hj\u00e4rtminutvolymen med 25 % under s\u00f6mn samtidigt som trycket i f\u00f6rmaken h\u00f6lls stabilt. Detta visades i simuleringar som utv\u00e4rderade ett friskt tillst\u00e5nd, samt i varierande niv\u00e5er av pulmonell hypertension. Sammantaget visar dessa resultat p\u00e5 enhetens f\u00f6rm\u00e5ga att anpassa sig till snabba \u00f6verg\u00e5ngar mellan fysiologiska tillst\u00e5nd.<\/p>\n<p>&#034;V\u00e5ra data visar att Realheart\u00ae TAH utm\u00e4rker sig genom sin f\u00f6rm\u00e5ga att m\u00f6jligg\u00f6ra olika niv\u00e5er av fysisk aktivitet f\u00f6r patienter som vill forts\u00e4tta att vara aktiva. Kombinationen av trycksensorbaserad \u00e5terkopplingskontroll och pumpmekanismens f\u00f6rm\u00e5ga att tillhandah\u00e5lla ett tr\u00e4ningsfl\u00f6de g\u00f6r den unik. Vi ser fram emot att genomf\u00f6ra ytterligare studier och utv\u00e4rdera den mot de produkter som f\u00f6r n\u00e4rvarande \u00e4r godk\u00e4nda&#034;, s\u00e4ger Dr. Seraina Dual, bitr\u00e4dande professor i biomedicinsk signalbehandling vid institutionen f\u00f6r biomedicinsk teknik och h\u00e4lsosystem, Kungliga Tekniska H\u00f6gskolan, Sverige.<\/p>\n<p>Studien bygger p\u00e5 ett gemensamt projekt mellan Realheart och KTH, som har byggt en toppmodern kardiovaskul\u00e4r \u201dhybridsimulator\u201d, som inkluderar en digital modell av hj\u00e4rta, lungor och k\u00e4rl som kan kopplas fysiskt till Realheart\u00ae TAH. Upps\u00e4ttningen m\u00f6jligg\u00f6r simuleringar av patientspecifika scenarier och f\u00f6rfining av pumpens styralgoritmer. Projektet m\u00f6jligg\u00f6rs av tv\u00e5 bidrag p\u00e5 totalt 8 miljoner kronor, finansierade av Vinnovas program Smart Elektronik, ett samarbete med Formas och Energimyndigheten.<\/p>\n<p>&#034;Objektiva studier av v\u00e5r enhets fysiologiska kontroll, utf\u00f6rda av experter inom forskningsomr\u00e5det, \u00e4r av avg\u00f6rande betydelse f\u00f6r att \u00f6ka v\u00e5r innovations \u00f6vergripande trov\u00e4rdighet och f\u00f6rtroende, visa dess prestanda och potential samt l\u00e4ra oss om omr\u00e5den d\u00e4r vi kan forts\u00e4tta att f\u00f6rb\u00e4ttra oss. Genom att anv\u00e4nda hybridsystemet kan vi genomf\u00f6ra snabba iterativa utvecklingscykler f\u00f6r att justera mjukvaran och snabbt testa ett stort antal olika fysiologiska scenarier&#034;, s\u00e4ger Ina Laura Perkins, VD, Realheart.<\/p>\n<p>Artikeln \u201dPhysiological Control of Realheart\u00ae Total Artificial Heart\u201d \u00e4r publicerad i Artificial Organs vol. 17 juni, 2025.<br \/><a href=\"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/aor.15036\" rel=\"noopener\" target=\"_blank\">https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/aor.15036<\/a><\/p>\n<\/div>\n<div class=\"mfn-footer mfn-contacts mfn-ddde9c982a0b\">\n<p><strong class=\"mfn-heading-1\">F\u00f6r mer information, kontakta:<\/strong><br \/>Ina Laura Perkins, VD<br \/>Tel: +46 (0) 70 406 49 21<br \/>E-post: <a href=\"mailto:inalaura.perkins@realheart.se\" rel=\"noopener\" target=\"_blank\">inalaura.perkins@realheart.se<\/a><br \/>Certified Adviser: Svensk Kapitalmarknadsgranskning AB, <a href=\"http:\/\/www.skmg.se\" rel=\"noopener\" target=\"_blank\">www.skmg.se<\/a><\/p>\n<\/div>\n<div class=\"mfn-footer mfn-about mfn-0285b54ad9f5\">\n<p><strong class=\"mfn-heading-1\">Om oss<\/strong><br \/>Scandinavian Real Heart AB (publ) utvecklar det f\u00f6rsta konstgjorda hj\u00e4rtat som efterliknar det m\u00e4nskliga hj\u00e4rtats form, funktion och blodfl\u00f6desm\u00f6nster. Dessa unika produktegenskaper ger helt nya m\u00f6jligheter att r\u00e4dda liv och ge patienter en god livskvalitet i v\u00e4ntan p\u00e5 en hj\u00e4rttransplantation. I framtiden kan konstgjorda hj\u00e4rtan ocks\u00e5 bli ett alternativ till transplantation f\u00f6r bredare grupper av patienter med sv\u00e5r hj\u00e4rtsvikt. Realheart\u00ae TAH (Total Artificial Heart) utv\u00e4rderas nu i omfattande prekliniska studier inf\u00f6r en f\u00f6rsta klinisk studie p\u00e5 patienter. Bolagets aktier \u00e4r upptagna till handel p\u00e5 Nasdaq Stockholm First North Growth Market. F\u00f6r mer information, bes\u00f6k <a href=\"https:\/\/realheart.se\/sv\/\" rel=\"noopener\" target=\"_blank\">https:\/\/realheart.se\/sv\/<\/a><\/p>\n<\/div>\n<div class=\"mfn-footer mfn-attachment mfn-attachment-general\">\n<p><strong class=\"mfn-heading-1\">Bifogade filer<\/strong><br \/><a class=\"mfn-generated mfn-primary\" href=\"https:\/\/storage.mfn.se\/24fe7987-aaa1-4f44-8bd0-27bc73fbd6ea\/realheart-publicerar-validerande-data-som-visar-hemodynamisk-balans-och-automatiserad-kontroll-av-hjartminutvolymen.pdf\" rel=\"noopener\" target=\"_blank\">Realheart publicerar validerande data som visar hemodynamisk balans och automatiserad kontroll av hj\u00e4rtminutvolymen<\/a><\/p>\n<\/div>\n<script>\n                Array.prototype.slice.call(document.querySelectorAll(\".mfn-footer.mfn-attachment\")).forEach(function (el) { el.remove() });\n            <\/script>\n        <div class=\"mfn-attachments-container\"><div class=\"mfn-attachment\"><a class=\"mfn-attachment-link\" href=\"https:\/\/storage.mfn.se\/24fe7987-aaa1-4f44-8bd0-27bc73fbd6ea\/realheart-publicerar-validerande-data-som-visar-hemodynamisk-balans-och-automatiserad-kontroll-av-hjartminutvolymen.pdf\"><span class=\"mfn-attachment-icon\"><img decoding=\"async\" src=\"https:\/\/storage.mfn.se\/24fe7987-aaa1-4f44-8bd0-27bc73fbd6ea\/realheart-publicerar-validerande-data-som-visar-hemodynamisk-balans-och-automatiserad-kontroll-av-hjartminutvolymen.pdf?type=jpg\"><\/span>Realheart publicerar validerande data som visar hemodynamisk balans och automatiserad kontroll av hj\u00e4rtminutvolymen<\/a><\/div><\/div>","protected":false},"excerpt":{"rendered":"<p>V\u00e4ster\u00e5s, Sverige, 18 juni 2025 &#8211; Scandinavian Real Heart AB (publ) meddelar idag att bolagets vetenskapliga samarbetspartner vid Kungliga Tekniska H\u00f6gskolan (KTH) har publicerat nya resultat i den vetenskapliga tidskriften Artificial Organs, som validerar Realheart\u00ae TAH:s funktion att skapa systemisk hemodynamisk balans, samt adaptivt justera systemets hj\u00e4rtminutvolym baserat p\u00e5 data fr\u00e5n trycksensorer. De nya resultaten&#8230;<\/p>\n","protected":false},"template":"","class_list":["post-7542","mfn_news","type-mfn_news","status-publish","hentry","mfn-news-tag-mfn-ci","mfn-news-tag-mfn-type-ir","mfn-news-tag-mfn-ext-nq","mfn-news-tag-mfn-ext-nq-company-announcement","mfn-news-tag-mfn","mfn-news-tag-mfn-ci-other","mfn-news-tag-mfn-lang-sv"],"acf":[],"aioseo_notices":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.5 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Realheart publicerar validerande data som visar hemodynamisk balans och automatiserad kontroll av hj\u00e4rtminutvolymen - Realheart<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/realheart.se\/mfn_news\/realheart-publicerar-validerande-data-som-visar-hemodynamisk-balans-och-automatiserad-kontroll-av-hjartminutvolymen\/\" \/>\n<meta property=\"og:locale\" content=\"sv_SE\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Realheart publicerar validerande data som visar hemodynamisk balans och automatiserad kontroll av hj\u00e4rtminutvolymen - Realheart\" \/>\n<meta property=\"og:description\" content=\"V\u00e4ster\u00e5s, Sverige, 18 juni 2025 &#8211; Scandinavian Real Heart AB (publ) meddelar idag att bolagets vetenskapliga samarbetspartner vid Kungliga Tekniska H\u00f6gskolan (KTH) har publicerat nya resultat i den vetenskapliga tidskriften Artificial Organs, som validerar Realheart\u00ae TAH:s funktion att skapa systemisk hemodynamisk balans, samt adaptivt justera systemets hj\u00e4rtminutvolym baserat p\u00e5 data fr\u00e5n trycksensorer. De nya resultaten...\" \/>\n<meta property=\"og:url\" content=\"https:\/\/realheart.se\/mfn_news\/realheart-publicerar-validerande-data-som-visar-hemodynamisk-balans-och-automatiserad-kontroll-av-hjartminutvolymen\/\" \/>\n<meta property=\"og:site_name\" content=\"Realheart\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Ber\u00e4knad l\u00e4stid\" \/>\n\t<meta name=\"twitter:data1\" content=\"3 minuter\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/realheart.se\\\/mfn_news\\\/realheart-publicerar-validerande-data-som-visar-hemodynamisk-balans-och-automatiserad-kontroll-av-hjartminutvolymen\\\/\",\"url\":\"https:\\\/\\\/realheart.se\\\/mfn_news\\\/realheart-publicerar-validerande-data-som-visar-hemodynamisk-balans-och-automatiserad-kontroll-av-hjartminutvolymen\\\/\",\"name\":\"Realheart publicerar validerande data som visar hemodynamisk balans och automatiserad kontroll av hj\u00e4rtminutvolymen - Realheart\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/realheart.se\\\/#website\"},\"datePublished\":\"2025-06-18T06:30:00+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/realheart.se\\\/mfn_news\\\/realheart-publicerar-validerande-data-som-visar-hemodynamisk-balans-och-automatiserad-kontroll-av-hjartminutvolymen\\\/#breadcrumb\"},\"inLanguage\":\"sv-SE\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/realheart.se\\\/mfn_news\\\/realheart-publicerar-validerande-data-som-visar-hemodynamisk-balans-och-automatiserad-kontroll-av-hjartminutvolymen\\\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/realheart.se\\\/mfn_news\\\/realheart-publicerar-validerande-data-som-visar-hemodynamisk-balans-och-automatiserad-kontroll-av-hjartminutvolymen\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"MFN News Items\",\"item\":\"https:\\\/\\\/realheart.se\\\/mfn_news\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Realheart publicerar validerande data som visar hemodynamisk balans och automatiserad kontroll av hj\u00e4rtminutvolymen\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/realheart.se\\\/#website\",\"url\":\"https:\\\/\\\/realheart.se\\\/\",\"name\":\"Realheart\",\"description\":\"\u00c4r ett medicintekniskt f\u00f6retag som utvecklar ett artificiellt hj\u00e4rta som ska r\u00e4dda liv p\u00e5 sv\u00e5rt hj\u00e4rtsjuka personer som st\u00e5r i transplantationsk\u00f6.\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/realheart.se\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"sv-SE\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Realheart publicerar validerande data som visar hemodynamisk balans och automatiserad kontroll av hj\u00e4rtminutvolymen - Realheart","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/realheart.se\/mfn_news\/realheart-publicerar-validerande-data-som-visar-hemodynamisk-balans-och-automatiserad-kontroll-av-hjartminutvolymen\/","og_locale":"sv_SE","og_type":"article","og_title":"Realheart publicerar validerande data som visar hemodynamisk balans och automatiserad kontroll av hj\u00e4rtminutvolymen - Realheart","og_description":"V\u00e4ster\u00e5s, Sverige, 18 juni 2025 &#8211; Scandinavian Real Heart AB (publ) meddelar idag att bolagets vetenskapliga samarbetspartner vid Kungliga Tekniska H\u00f6gskolan (KTH) har publicerat nya resultat i den vetenskapliga tidskriften Artificial Organs, som validerar Realheart\u00ae TAH:s funktion att skapa systemisk hemodynamisk balans, samt adaptivt justera systemets hj\u00e4rtminutvolym baserat p\u00e5 data fr\u00e5n trycksensorer. De nya resultaten...","og_url":"https:\/\/realheart.se\/mfn_news\/realheart-publicerar-validerande-data-som-visar-hemodynamisk-balans-och-automatiserad-kontroll-av-hjartminutvolymen\/","og_site_name":"Realheart","twitter_card":"summary_large_image","twitter_misc":{"Ber\u00e4knad l\u00e4stid":"3 minuter"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/realheart.se\/mfn_news\/realheart-publicerar-validerande-data-som-visar-hemodynamisk-balans-och-automatiserad-kontroll-av-hjartminutvolymen\/","url":"https:\/\/realheart.se\/mfn_news\/realheart-publicerar-validerande-data-som-visar-hemodynamisk-balans-och-automatiserad-kontroll-av-hjartminutvolymen\/","name":"Realheart publicerar validerande data som visar hemodynamisk balans och automatiserad kontroll av hj\u00e4rtminutvolymen - Realheart","isPartOf":{"@id":"https:\/\/realheart.se\/#website"},"datePublished":"2025-06-18T06:30:00+00:00","breadcrumb":{"@id":"https:\/\/realheart.se\/mfn_news\/realheart-publicerar-validerande-data-som-visar-hemodynamisk-balans-och-automatiserad-kontroll-av-hjartminutvolymen\/#breadcrumb"},"inLanguage":"sv-SE","potentialAction":[{"@type":"ReadAction","target":["https:\/\/realheart.se\/mfn_news\/realheart-publicerar-validerande-data-som-visar-hemodynamisk-balans-och-automatiserad-kontroll-av-hjartminutvolymen\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/realheart.se\/mfn_news\/realheart-publicerar-validerande-data-som-visar-hemodynamisk-balans-och-automatiserad-kontroll-av-hjartminutvolymen\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"MFN News Items","item":"https:\/\/realheart.se\/mfn_news\/"},{"@type":"ListItem","position":2,"name":"Realheart publicerar validerande data som visar hemodynamisk balans och automatiserad kontroll av hj\u00e4rtminutvolymen"}]},{"@type":"WebSite","@id":"https:\/\/realheart.se\/#website","url":"https:\/\/realheart.se\/","name":"Realheart","description":"\u00c4r ett medicintekniskt f\u00f6retag som utvecklar ett artificiellt hj\u00e4rta som ska r\u00e4dda liv p\u00e5 sv\u00e5rt hj\u00e4rtsjuka personer som st\u00e5r i transplantationsk\u00f6.","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/realheart.se\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"sv-SE"}]}},"_links":{"self":[{"href":"https:\/\/realheart.se\/sv\/wp-json\/wp\/v2\/mfn_news\/7542","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/realheart.se\/sv\/wp-json\/wp\/v2\/mfn_news"}],"about":[{"href":"https:\/\/realheart.se\/sv\/wp-json\/wp\/v2\/types\/mfn_news"}],"wp:attachment":[{"href":"https:\/\/realheart.se\/sv\/wp-json\/wp\/v2\/media?parent=7542"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}